<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Commercial Refrigeration - ADK Kooling</title>
	<atom:link href="https://adk.co.uk/category/commercial-refrigeration/feed/" rel="self" type="application/rss+xml" />
	<link>https://adk.co.uk</link>
	<description>Air Conditioning &#38; Refrigeration Specialists</description>
	<lastBuildDate>Thu, 07 May 2026 11:30:18 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.11</generator>

<image>
	<url>https://adk.co.uk/wp-content/uploads/2019/04/cropped-54315-6-ice-cube-hd-free-download-png-hq-32x32.png</url>
	<title>Commercial Refrigeration - ADK Kooling</title>
	<link>https://adk.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Why Your Walk-In Freezer Struggles in Summer – And How to Stop It</title>
		<link>https://adk.co.uk/why-your-walk-in-freezer-struggles-in-summer-and-how-to-stop-it/</link>
		
		<dc:creator><![CDATA[Rana]]></dc:creator>
		<pubDate>Tue, 05 May 2026 11:05:36 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11798</guid>

					<description><![CDATA[<p>Summer can be one of the most challenging times of year for commercial refrigeration systems in the UK. As temperatures rise, many businesses begin to notice their walk-in freezer struggling to maintain the correct temperature. For restaurants, supermarkets, hotels, catering businesses and food storage facilities, this can quickly become a serious problem. A walk-in freezer...</p>
<p>The post <a href="https://adk.co.uk/why-your-walk-in-freezer-struggles-in-summer-and-how-to-stop-it/">Why Your Walk-In Freezer Struggles in Summer – And How to Stop It</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="wp-post" data-elementor-id="11798" class="elementor elementor-11798" data-elementor-post-type="post">
				<div class="elementor-element elementor-element-6b55a6d e-flex e-con-boxed e-con e-parent" data-id="6b55a6d" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-34f087e2 elementor-widget elementor-widget-text-editor" data-id="34f087e2" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p data-start="5018" data-end="5245">Summer can be one of the most challenging times of year for commercial refrigeration systems in the UK. As temperatures rise, many businesses begin to notice their <a href="https://www.belfastlive.co.uk/whats-on/food-drink-news/how-long-food-stay-safe-25355297">walk-in freezer struggling to maintain the correct temperature.</a></p><p data-start="5247" data-end="5377">For restaurants, supermarkets, hotels, catering businesses and food storage facilities, this can quickly become a serious problem.</p><p data-start="5379" data-end="5511">A walk-in freezer working harder than normal not only increases energy costs but can also risk stock damage, breakdowns and costly downtime.</p><p data-start="5513" data-end="5571">So, why does this happen — and what can you do to stop it?</p><h4 data-section-id="1uquq1" data-start="5573" data-end="5619">Why Walk-In Freezers Struggle During Summer</h4><p data-start="5621" data-end="5754">Commercial walk-in freezers are designed to operate in demanding conditions, but warmer weather creates extra pressure on the system.</p><p data-start="5756" data-end="5881">During summer, the <a href="https://adk.co.uk/services/coldrooms/">walk-in freezer</a> must remove far more heat from the surrounding environment to maintain safe internal temperatures.</p><p data-start="5883" data-end="5977">If the system already has underlying issues, warmer conditions often expose them very quickly.</p><h4 data-section-id="1pd1e9v" data-start="5979" data-end="6022">Common Causes of Summer Freezer Problems</h4><h6 data-section-id="vqbhf2" data-start="6024" data-end="6049">Frequent Door Opening</h6><p data-start="6051" data-end="6123">One of the biggest causes of temperature issues is excessive door usage.</p><p data-start="6125" data-end="6259">Every time the freezer door opens, warm air enters the room and forces the refrigeration system to work harder to recover temperature.</p><p data-start="6261" data-end="6368">Busy kitchens, retail stores and food distribution sites often experience this during peak trading periods.</p><h4 data-section-id="1aci41m" data-start="6370" data-end="6389">Poor Door Seals</h4><p data-start="6391" data-end="6471">Damaged or worn door seals allow warm air to continuously leak into the freezer.</p><p data-start="6473" data-end="6559">Even small gaps can create significant temperature fluctuations during warmer weather.</p><p data-start="6561" data-end="6617">Checking seals regularly is a simple but important step.</p><h4 data-section-id="1cbutaf" data-start="6619" data-end="6644">Dirty Condenser Coils</h4><p data-start="6646" data-end="6793">Condenser coils help release heat from the refrigeration system. When they become blocked with dust, grease or debris, heat cannot escape properly.</p><p data-start="6795" data-end="6861">This reduces efficiency and places extra strain on the compressor.</p><p data-start="6863" data-end="6930">During summer, dirty coils can severely affect freezer performance.</p><h4 data-section-id="m2cfda" data-start="6932" data-end="6959">Overloading the Freezer</h4><p data-start="6961" data-end="7054">Overstocking can restrict airflow inside the freezer and prevent cold air from circulating evenly.</p><p data-start="7056" data-end="7141">This often leads to inconsistent temperatures and overworked refrigeration equipment.</p><h4 data-section-id="19kjxtj" data-start="7143" data-end="7190">Poor Ventilation Around the Condensing Unit</h4><p data-start="7192" data-end="7266">Outdoor condensing units need adequate airflow to remove heat effectively.</p><p data-start="7268" data-end="7380">If the surrounding area is blocked or exposed to excessive heat, the system may struggle to operate efficiently.</p><h4 data-section-id="m9reao" data-start="7382" data-end="7425">Signs Your Walk-In Freezer Is Struggling</h4><p data-start="7427" data-end="7456">Common warning signs include:</p><ul data-start="7458" data-end="7639"><li data-section-id="1xlnzkp" data-start="7458" data-end="7472">Ice build-up</li><li data-section-id="guqd14" data-start="7473" data-end="7503">Rising internal temperatures</li><li data-section-id="kjwdn9" data-start="7504" data-end="7534">Excessive compressor running</li><li data-section-id="9rldm6" data-start="7535" data-end="7561">Higher electricity bills</li><li data-section-id="mb15cw" data-start="7562" data-end="7578">Unusual noises</li><li data-section-id="1mfw9zq" data-start="7579" data-end="7611">Soft or partially thawed stock</li><li data-section-id="4b41f1" data-start="7612" data-end="7639">Condensation around doors</li></ul><p data-start="7641" data-end="7709">Ignoring these signs can eventually lead to complete system failure.</p><h4 data-section-id="1qgrwoq" data-start="7711" data-end="7760">How to Stop Walk-In Freezer Problems in Summer</h4><h6 data-section-id="660o3a" data-start="7762" data-end="7798">Arrange Preventive Maintenance</h6><p data-start="7800" data-end="7885">Regular refrigeration servicing is one of the best ways to prevent summer breakdowns.</p><p data-start="7887" data-end="8006">Professional engineers can identify worn components, refrigerant issues or airflow problems before they become serious.</p><h4 data-section-id="16dy45n" data-start="8008" data-end="8038">Keep Condenser Coils Clean</h4><p data-start="8040" data-end="8112">Routine coil cleaning helps improve heat transfer and system efficiency.</p><p data-start="8114" data-end="8179">This is especially important before summer temperatures increase.</p><h4 data-section-id="8v946v" data-start="8181" data-end="8205">Reduce Door Openings</h4><p data-start="8207" data-end="8311">Where possible, limit unnecessary door usage and ensure staff avoid leaving doors open for long periods.</p><p data-start="8313" data-end="8392">Strip curtains or automatic door closers may also help reduce temperature loss.</p><h4 data-section-id="11gpk21" data-start="8394" data-end="8424">Check Temperature Settings</h4><p data-start="8426" data-end="8499">Make sure freezer temperatures are correctly set and monitored regularly.</p><p data-start="8501" data-end="8572">Unexpected temperature increases should always be investigated quickly.</p><h4 data-section-id="81w1mj" data-start="8574" data-end="8595">Avoid Overloading</h4><p data-start="8597" data-end="8669">Allow enough space for air to circulate properly throughout the freezer.</p><p data-start="8671" data-end="8729">Poor airflow can significantly reduce cooling performance.</p><h4 data-section-id="akw4oz" data-start="8731" data-end="8764">Why Summer Preparation Matters</h4><p data-start="8766" data-end="8904">Commercial refrigeration breakdowns often happen during the busiest trading periods — exactly when businesses can least afford disruption.</p><p data-start="8906" data-end="8954">Preventative maintenance before summer can help:</p><ul data-start="8956" data-end="9086"><li data-section-id="n4r6s2" data-start="8956" data-end="8977">Reduce energy costs</li><li data-section-id="fg5wuf" data-start="8978" data-end="9002">Protect valuable stock</li><li data-section-id="4j61hc" data-start="9003" data-end="9030">Improve system efficiency</li><li data-section-id="1af4n0h" data-start="9031" data-end="9058">Prevent emergency repairs</li><li data-section-id="1y1vp0u" data-start="9059" data-end="9086">Extend equipment lifespan</li></ul><p data-start="9107" data-end="9240">If your walk-in freezer struggles during summer, it is usually a sign that the system is under pressure or already developing faults.</p><p data-start="9242" data-end="9330">Ignoring the issue can lead to expensive repairs, stock loss and operational disruption.</p><p data-start="9332" data-end="9533">Regular maintenance, proper airflow, clean components and good daily practices all play an important role in keeping commercial refrigeration systems running efficiently during warmer months in the UK.</p><p data-start="9535" data-end="9628" data-is-last-node="" data-is-only-node="">A proactive approach now can help prevent serious refrigeration problems later in the season.</p><p><!-- /wp:paragraph --></p>								</div>
				</div>
					</div>
				</div>
				</div><p>The post <a href="https://adk.co.uk/why-your-walk-in-freezer-struggles-in-summer-and-how-to-stop-it/">Why Your Walk-In Freezer Struggles in Summer – And How to Stop It</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cold Room Working Then Suddenly Getting Warm- What&#8217;s Really Happening</title>
		<link>https://adk.co.uk/cold-room-working-then-suddenly-getting-warm-whats-really-happening/</link>
		
		<dc:creator><![CDATA[Rana]]></dc:creator>
		<pubDate>Tue, 21 Apr 2026 12:24:21 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11734</guid>

					<description><![CDATA[<p>A cold room is usually noticed a bit too late. Everything seemed fine earlier. The cold room was holding temperature, stock was safe, no alarms, no obvious signs of trouble. Then someone walks in and pauses. “It doesn’t feel right in here.” You check the display. The temperature is higher than it should be. Not...</p>
<p>The post <a href="https://adk.co.uk/cold-room-working-then-suddenly-getting-warm-whats-really-happening/">Cold Room Working Then Suddenly Getting Warm- What’s Really Happening</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="wp-post" data-elementor-id="11734" class="elementor elementor-11734" data-elementor-post-type="post">
				<div class="elementor-element elementor-element-685c80a6 e-flex e-con-boxed e-con e-parent" data-id="685c80a6" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-42f6d915 elementor-widget elementor-widget-text-editor" data-id="42f6d915" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p data-start="219" data-end="255">A <a href="https://adk.co.uk/services/coldrooms/">cold room</a> is usually noticed a bit too late. Everything seemed fine earlier. The cold room was holding temperature, stock was safe, no alarms, no obvious signs of trouble. Then someone walks in and pauses.</p><p data-start="419" data-end="451">“It doesn’t feel right in here.”</p><p data-start="453" data-end="620">You check the display. The temperature is higher than it should be. Not massively at first — just enough to raise concern. But give it another hour, and it’s climbing.</p><p data-start="622" data-end="641">Now it’s a problem.</p><p data-start="643" data-end="910">A cold room working normally and then suddenly getting warm is one of the most frustrating faults to deal with because it feels unpredictable. One minute, everything is stable; the next, you’re dealing with potential stock loss, disruption, and pressure to act quickly. The key thing to understand is this: systems don’t usually fail without reason. When a cold room temperature rises suddenly, something has changed — either mechanically, electrically, or in the way the system is operating.</p><h5 data-section-id="sj74u4" data-start="1141" data-end="1207"><span role="text"><strong data-start="1144" data-end="1207">When It Happens Suddenly, Start Thinking About What Changed</strong></span></h5><p data-start="1209" data-end="1344">If the <a href="https://adk.co.uk/services/coldrooms/">cold room</a> has been running fine and then quickly starts warming up, the cause is often linked to something that’s just happened.</p><p data-start="1346" data-end="1618">Power issues are one of the first things to consider. A brief interruption in supply, even a small one, can stop the system from running properly. In some cases, the unit may not restart automatically, leaving the room to slowly warm without anyone noticing straight away.</p><p data-start="1620" data-end="1926">Then there’s the compressor — the part of the system responsible for actually doing the cooling. If that stops working, even briefly, the temperature inside the cold room begins to rise quite quickly. From the outside, the system might still look like it’s running, but without proper cooling taking place.</p><p data-start="1928" data-end="2198">Another common situation is airflow being affected. If fans stop working or become restricted, cold air isn’t circulated properly. You might find certain areas of the cold room getting warmer faster than others, even though the system itself hasn’t completely shut down.</p><h5 data-section-id="1vzar6j" data-start="2205" data-end="2263"><span role="text"><strong data-start="2208" data-end="2263">The Hidden Culprit: Condensate and Safety Shut-Offs</strong></span></h5><p data-start="2265" data-end="2331">One issue that catches a lot of people out is condensate build-up.</p><p data-start="2333" data-end="2550">Cold rooms naturally produce moisture as part of the cooling process. That water needs somewhere to go. If the drainage system becomes blocked, or a pump fails, the system may shut itself down to prevent water damage.</p><p data-start="2552" data-end="2719">From your point of view, it looks like the cold room has simply stopped cooling. But in reality, the system has done exactly what it’s designed to do — protect itself.</p><p data-start="2721" data-end="2774">It’s a small component causing a much bigger problem.</p><h5 data-section-id="yy7c9s" data-start="2781" data-end="2816"><span role="text"><strong data-start="2784" data-end="2816">Why It Often Feels So Sudden</strong></span></h5><p data-start="2818" data-end="2910">In truth, many of these faults don’t appear instantly. They build quietly in the background.</p><ul><li data-start="2912" data-end="3025">A filter gradually becomes blocked.</li><li data-start="2912" data-end="3025">A component starts to wear out.</li><li data-start="2912" data-end="3025">A system begins to struggle under load.</li></ul><p data-start="3027" data-end="3120">But you don’t notice it until the point where performance drops enough to affect temperature.</p><p data-start="3122" data-end="3203">That’s why it feels sudden — even though the issue has been developing over time.</p><h5 data-section-id="thmzfc" data-start="3210" data-end="3264"><span role="text"><strong data-start="3213" data-end="3264">When the Cold Room Starts Warming, Time Matters</strong></span></h5><p data-start="3266" data-end="3328">Once the temperature begins to rise, the focus shifts quickly.</p><p data-start="3330" data-end="3397">It’s no longer just about the system — it’s about what’s inside it.</p><p data-start="3399" data-end="3540">Food, stock, and temperature-sensitive goods all have limits. The longer the cold room stays above its set temperature, the greater the risk.</p><p data-start="3542" data-end="3725">In busy environments like restaurants, commercial kitchens, or storage facilities, this can escalate quickly. What starts as a technical issue becomes a business problem within hours.</p><h5 data-section-id="mg1zsz" data-start="3732" data-end="3768"><span role="text"><strong data-start="3735" data-end="3768">What You Can Do Straight Away</strong></span></h5><p data-start="3770" data-end="3887">If you notice your cold room getting warm, there are a few practical steps you can take while arranging a proper fix. Keep the door closed as much as possible. Every time it’s opened, warm air enters and makes the situation worse. It sounds simple, but it makes a real difference.</p><p data-start="4053" data-end="4178">Avoid adding new stock to the room. Introducing warmer items increases the internal load and pushes the temperature higher. If possible, check whether the system is actually running. Listen for the outdoor unit, check the controller, and see if anything looks obviously out of place.</p><p data-start="4341" data-end="4405">But beyond that, it’s about acting quickly rather than guessing.</p><h5 data-section-id="1g1g51f" data-start="4412" data-end="4444"><span role="text"><strong data-start="4415" data-end="4444">When It Needs an Engineer</strong></span></h5><p data-start="4446" data-end="4544">If the cold room temperature is rising and not recovering, it’s time to get it looked at properly.</p><p data-start="4546" data-end="4694">These systems are designed to maintain stable conditions. When they can’t, there’s always a reason — and it’s rarely something that resolves itself.</p><p data-start="4696" data-end="4751">Delaying the call often makes things worse, not better.</p><h5 data-section-id="6fs0mq" data-start="4758" data-end="4792"><span role="text"><strong data-start="4761" data-end="4792">Stopping It from Happening Again</strong></span></h5><p data-start="4794" data-end="4870">Most situations like this come down to one thing: lack of routine attention.</p><p data-start="4872" data-end="5047">Cold rooms work hard. They run for long hours, often without interruption. Over time, small issues develop — and without maintenance, they eventually show up as bigger faults.</p><p data-start="5049" data-end="5077">Regular checks help prevent:</p><ul data-start="5078" data-end="5187"><li data-section-id="97a0ed" data-start="5078" data-end="5106">Blocked drainage systems</li><li data-section-id="1fs0uqv" data-start="5107" data-end="5131">Airflow restrictions</li><li data-section-id="7u7qx7" data-start="5132" data-end="5166">Component wear is going unnoticed</li><li data-section-id="uj1n26" data-start="5167" data-end="5187">Sudden shutdowns</li></ul><p data-start="5189" data-end="5307">It’s not about overcomplicating things. It’s about keeping the system in a condition where it can do its job reliably. A cold room doesn’t just stop working for no reason. When it goes from holding temperature to getting warm, it’s a sign that something has shifted — and that shift needs attention. The sooner it’s understood, the easier it is to fix. Leave it too long, and it becomes something else entirely.</p><h5 data-section-id="80ffv5" data-start="5638" data-end="5663"><span role="text"><strong data-start="5641" data-end="5663">Need Help Quickly?</strong></span></h5><p data-start="5665" data-end="5773">If your <a href="https://adk.co.uk/services/coldrooms/">cold room</a> is getting warm and you need it sorted properly, don’t wait for the situation to escalate.</p><p data-start="5775" data-end="5900"><strong data-start="5775" data-end="5812">Call ADK Kooling on 020 3909 9729</strong><br data-start="5812" data-end="5815" />We’ll identify the issue and get your cold room back to the temperature it should be.</p><p><!-- /wp:paragraph --></p>								</div>
				</div>
					</div>
				</div>
				</div><p>The post <a href="https://adk.co.uk/cold-room-working-then-suddenly-getting-warm-whats-really-happening/">Cold Room Working Then Suddenly Getting Warm- What’s Really Happening</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Commercial Fridge not cooling?</title>
		<link>https://adk.co.uk/commercial-fridge-not-cooling-2/</link>
		
		<dc:creator><![CDATA[Rana]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 15:43:46 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11705</guid>

					<description><![CDATA[<p>When a cold room, commercial fridge, or chiller cabinet starts running warm, every minute counts. Food safety, stock value and service levels are at risk, and guesswork can make matters worse. This guide provides safe, practical checks you can carry out quickly to help stabilise temperatures and gather clear information for the engineer. We outline...</p>
<p>The post <a href="https://adk.co.uk/commercial-fridge-not-cooling-2/">Commercial Fridge not cooling?</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="wp-post" data-elementor-id="11705" class="elementor elementor-11705" data-elementor-post-type="post">
				<div class="elementor-element elementor-element-685c80a6 e-flex e-con-boxed e-con e-parent" data-id="685c80a6" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-42f6d915 elementor-widget elementor-widget-text-editor" data-id="42f6d915" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p data-start="114" data-end="452">When a cold room, <a href="https://adk.co.uk/commercial-refrigeration/breakdowns-repair/">commercial fridge</a>, or chiller cabinet starts running warm, every minute counts. Food safety, stock value and service levels are at risk, and guesswork can make matters worse. This guide provides safe, practical checks you can carry out quickly to help stabilise temperatures and gather clear information for the engineer.</p><p data-start="454" data-end="690">We outline what to check first, what to record, and when to stop and call an F-Gas certified engineer. We also explain our rapid 6-hour response across London, typical van stock parts, and sensible steps to protect stock while you wait.</p><p data-start="692" data-end="828">If in doubt at any stage, keep doors closed and contact our service desk. The aim is to preserve stock and prevent damage to the system.</p><p data-start="830" data-end="916"><strong data-start="830" data-end="846">Safety first</strong><br data-start="846" data-end="849" />Before carrying out any checks, ensure staff understand the basics:</p><ul data-start="918" data-end="1279"><li data-section-id="9zldnb" data-start="918" data-end="1033">Do not open sealed refrigeration circuits. Refrigerant work must be carried out by an F-Gas certified engineer.</li><li data-section-id="4hcim3" data-start="1034" data-end="1210">Take care around moving fans and live electrics. Only isolate power where instructed and where it will not risk a full defrost of a freezer without a plan to protect stock.</li><li data-section-id="1my2qzv" data-start="1211" data-end="1279">Keep doors closed as much as possible to limit temperature rise.</li></ul><p data-start="1281" data-end="1359"><strong data-start="1281" data-end="1310">Quick stabilisation steps</strong><br data-start="1310" data-end="1313" />Simple actions can slow temperature increases:</p><ul data-start="1361" data-end="1747"><li data-section-id="1f9xakr" data-start="1361" data-end="1424">Minimise door openings. Use a single person for retrievals.</li><li data-section-id="1ps66t9" data-start="1425" data-end="1531">Consolidate stock into the coldest cabinet or area of a walk-in, leaving space around evaporator fans.</li><li data-section-id="sm7507" data-start="1532" data-end="1626">Use ice packs or frozen gel packs to help maintain temperature in fridges where available.</li><li data-section-id="2ld94e" data-start="1627" data-end="1747">Move high-risk items first in line with your HACCP plan, prioritising raw fish, dairy and cooked ready-to-eat foods.</li></ul><p data-start="1749" data-end="1877"><strong data-start="1749" data-end="1797">Step-by-step checks you can carry out safely</strong><br data-start="1797" data-end="1800" />Work through these in order and record findings with times on your log sheet.</p><p data-start="1879" data-end="2295"><strong data-start="1879" data-end="1918">Power supply and isolation switches</strong><br data-start="1918" data-end="1921" />Check that the cabinet or condensing unit has power. Inspect local isolators and fused spurs. Has the outdoor unit been switched off during cleaning or deliveries?<br data-start="2084" data-end="2087" />Confirm the plug or spur fuse has not blown. Do not increase fuse ratings.<br data-start="2161" data-end="2164" />If the controller is blank, attempt a controlled power cycle once at the isolator and note the time and any fault codes on restart.</p><p data-start="2297" data-end="2651"><strong data-start="2297" data-end="2331">Door seals, hinges and closing</strong><br data-start="2331" data-end="2334" />Carry out a paper test: close a sheet of paper in the door and pull. If it slips out easily at multiple points, the gasket may be worn or the door misaligned.<br data-start="2492" data-end="2495" />Check for split or flattened seals, damaged hinges or poor alignment preventing full closure.<br data-start="2588" data-end="2591" />Listen for door alarms and ensure the door latches properly.</p><p data-start="2653" data-end="2977"><strong data-start="2653" data-end="2685">Airflow and product stacking</strong><br data-start="2685" data-end="2688" />Inside: ensure nothing blocks evaporator inlets or outlets. Leave at least a hand’s width clearance around fan guards.<br data-start="2806" data-end="2809" />Outside: check the condenser has at least 300 mm of clear space and is not obstructed by boxes, linen or stock. Poor airflow increases pressure and raises temperatures.</p><p data-start="2979" data-end="3281"><strong data-start="2979" data-end="3031">Condenser cleanliness (external or undercounter)</strong><br data-start="3031" data-end="3034" />Look for dust, flour or grease build-up on condenser fins. If safe, gently brush or vacuum along the fin direction. Do not use sharp tools or pressure washers.<br data-start="3193" data-end="3196" />Kitchen environments often require monthly light cleaning and periodic deep cleaning.</p><p data-start="3283" data-end="3638"><strong data-start="3283" data-end="3319">Evaporator condition and defrost</strong><br data-start="3319" data-end="3322" />If visible, check for heavy frost or ice build-up. Ice bridging fins or covering fan hubs indicates a defrost or airflow issue.<br data-start="3449" data-end="3452" />Trigger a manual defrost from the controller if your HACCP plan allows and stock is protected. Do not chip ice away.<br data-start="3568" data-end="3571" />Ensure defrost cycles are appropriate for operating hours and load.</p><p data-start="3640" data-end="3870"><strong data-start="3640" data-end="3668">Drain and tray blockages</strong><br data-start="3668" data-end="3671" />Check the condensate tray and drain line. Standing water, debris or overflow can refreeze and restrict airflow.<br data-start="3782" data-end="3785" />Clear visible debris at the inlet. If blocked further along, record for the engineer.</p><p data-start="3872" data-end="4176"><strong data-start="3872" data-end="3915">Temperature probe position and accuracy</strong><br data-start="3915" data-end="3918" />Ensure the probe is in free air, not touching surfaces or sitting in water.<br data-start="3993" data-end="3996" />If using a product simulation bottle, confirm it is correctly filled and positioned away from the door.<br data-start="4099" data-end="4102" />Compare the display reading with a calibrated thermometer and record both.</p><p data-start="4178" data-end="4526"><strong data-start="4178" data-end="4207">Fans and operating sounds</strong><br data-start="4207" data-end="4210" />Check evaporator fans run when the compressor is operating. Lack of airflow often results in warm conditions despite a cold coil.<br data-start="4339" data-end="4342" />Listen at the condensing unit: buzzing without starting, repeated clicking or tripping may indicate component or compressor failure. Stop further restart attempts and call for service.</p><p data-start="4528" data-end="4721"><strong data-start="4528" data-end="4570">Stop and call immediately if you find:</strong><br data-start="4570" data-end="4573" />Heavy icing on the evaporator, repeated tripping, compressor short cycling, oily residue on pipework (possible refrigerant leak), or burning smells.</p><p data-start="4723" data-end="5120"><strong data-start="4723" data-end="4767">When to call an F-Gas certified engineer</strong><br data-start="4767" data-end="4770" />Call promptly if you suspect a refrigerant leak, electrical fault, failed fan motor, defrost heater issue or controller fault. These require specialist tools and certified handling. We carry nitrogen for pressure testing, electronic leak detectors, start components, defrost heaters, fan motors and common controllers to maximise first-visit repairs.</p><p data-start="5122" data-end="5192"><strong data-start="5122" data-end="5151">What to tell the engineer</strong><br data-start="5151" data-end="5154" />Clear information speeds up diagnosis:</p><ul data-start="5194" data-end="5426"><li data-section-id="1y9be74" data-start="5194" data-end="5220">Unit type and location</li><li data-section-id="13ol2s8" data-start="5221" data-end="5252">Make and model if available</li><li data-section-id="q90zp8" data-start="5253" data-end="5305">Symptoms, fault codes and checklist observations</li><li data-section-id="15llcky" data-start="5306" data-end="5370">Latest HACCP temperatures and time since last normal reading</li><li data-section-id="10vqdgz" data-start="5371" data-end="5426">Any recent cleaning, electrical work or door damage</li></ul><p data-start="5428" data-end="5524"><strong data-start="5428" data-end="5464">Temporary steps to protect stock</strong><br data-start="5464" data-end="5467" />If temperatures are rising and an engineer is on the way:</p><ul data-start="5526" data-end="5806"><li data-section-id="1q8kwaw" data-start="5526" data-end="5582">Keep doors closed and lights off to reduce heat load</li><li data-section-id="1sltldw" data-start="5583" data-end="5648">Reduce product density near the evaporator to improve airflow</li><li data-section-id="1p9f2j3" data-start="5649" data-end="5724">For walk-ins, place sealed ice packs on upper shelves, away from probes</li><li data-section-id="1vft1ng" data-start="5725" data-end="5806">Move high-risk items to another working unit or blast chiller where available</li></ul><p data-start="5808" data-end="5923"><strong data-start="5808" data-end="5846">Our response and typical van stock</strong><br data-start="5846" data-end="5849" />We provide a 6-hour response across London. Our engineers typically carry:</p><ul data-start="5925" data-end="6221"><li data-section-id="1n9s5b0" data-start="5925" data-end="5976">Start capacitors, relays, fan motors and blades</li><li data-section-id="amoq8u" data-start="5977" data-end="6039">Defrost heaters, termination thermostats and drain heaters</li><li data-section-id="6y9mm1" data-start="6040" data-end="6091">Controllers, door seals, contactors and sensors</li><li data-section-id="nbfctn" data-start="6092" data-end="6172">Leak detection equipment, nitrogen, recovery units and F-Gas compliant tools</li><li data-section-id="bxq4a6" data-start="6173" data-end="6221">Cleaning equipment for condensers and drains</li></ul><p data-start="6223" data-end="6336">If a specialist part is required, we will source it promptly and advise on safe stock management in the meantime.</p><p data-start="6338" data-end="6661"><strong data-start="6338" data-end="6364">Repair or replacement?</strong><br data-start="6364" data-end="6367" />As a guide, if repair costs are below around 40% of replacement and the unit is in reasonable condition, repair is often worthwhile. If costs exceed around 60% or the unit is near end of life, replacement may be more economical. We will provide clear options and expected lifespan after repair.</p><p data-start="6663" data-end="6820">With proper maintenance, a commercial fridge typically lasts 8 to 12 years. Poor airflow, dirty condensers and worn door seals can significantly reduce this.</p><p><!-- /wp:paragraph --></p>								</div>
				</div>
					</div>
				</div>
				</div><p>The post <a href="https://adk.co.uk/commercial-fridge-not-cooling-2/">Commercial Fridge not cooling?</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Supermarket Refrigeration Case Running Warm — What to Check</title>
		<link>https://adk.co.uk/supermarket-refrigeration-case-running-warm/</link>
		
		<dc:creator><![CDATA[Omar]]></dc:creator>
		<pubDate>Fri, 13 Mar 2026 11:17:38 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11517</guid>

					<description><![CDATA[<p>The store manager gets the alert at 7 AM: dairy case reading 8°C. It should be sitting between 2°C and 4°C. By the time they reach the shop floor, the temperature is still climbing. Product is at risk. Food safety regs say they need to act now — log the breach, start pulling stock, and...</p>
<p>The post <a href="https://adk.co.uk/supermarket-refrigeration-case-running-warm/">Supermarket Refrigeration Case Running Warm — What to Check</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>The store manager gets the alert at 7 AM: dairy case reading 8°C. It should be sitting between 2°C and 4°C. By the time they reach the shop floor, the temperature is still climbing. Product is at risk. Food safety regs say they need to act now — log the breach, start pulling stock, and get an engineer on site before the losses get worse.</p>



<p>Supermarket refrigeration isn&#8217;t like a domestic fridge. These are complex multi-case systems running off central compressor racks, with individual solenoid valves, expansion valves, and evaporators for each display case. When one case runs warm, the cause could be local to that specific case or systemic across the entire rack. Here&#8217;s how to work through it methodically.</p>

<p>Faults like this are common across commercial sites in <a href="https://adk.co.uk/air-conditioning-refrigeration-north-london/">North London</a>. Enrolling in a <a href="https://adk.co.uk/emergency-breakdown-service/">emergency breakdown service</a> schedule helps catch the warning signs early, reducing the chance you will ever need an <a href="https://adk.co.uk/commercial-refrigeration-installation/">refrigeration installation</a>.</p>



<h2 class="wp-block-heading">Iced-Up Evaporator — Defrost Failure</h2>



<p>The most common cause of a single case running warm. Every refrigeration display case runs scheduled defrost cycles — typically electric heater defrosts — to clear frost from the evaporator coil. If the defrost heater element fails, the defrost timer malfunctions, or the termination thermostat is faulty, ice accumulates on the evaporator with every cooling cycle until airflow is completely blocked.</p>



<p>You can often identify this without opening the case panels. If the air curtain across the front of the case feels weak or non-existent, the case temperature is rising steadily, and there&#8217;s visible frost on the back panel or around the air discharge grille, you&#8217;re almost certainly looking at a defrost failure. The evaporator needs a manual defrost to clear the ice — which takes time and means the case is out of service — followed by diagnosis and repair of whichever defrost component has failed.</p>



<h2 class="wp-block-heading">Failed Solenoid Valve on the Liquid Line</h2>



<p>Each display case on a centralised rack system has a liquid line solenoid valve. When the case thermostat calls for cooling, this solenoid opens and allows liquid refrigerant to flow to the case&#8217;s expansion valve and into the evaporator. If the solenoid fails in the closed position, no refrigerant reaches that case. The evaporator warms to ambient temperature, the case temperature climbs, and everything else on the rack continues operating normally — because the fault is isolated to that one valve.</p>



<p>Diagnosis is straightforward. Check for voltage at the solenoid coil when the case thermostat is calling for cooling. Voltage present but the valve not opening means the coil or the valve mechanism has failed. Listen for the click when the solenoid should energise. No click with voltage present confirms a dead coil. Solenoid coils are one of the most common spares a refrigeration engineer carries.</p>



<h2 class="wp-block-heading">Blocked Expansion Valve</h2>



<p>The thermostatic expansion valve (TXV) meters liquid refrigerant into the evaporator at precisely the rate needed for efficient heat exchange. These valves have small internal orifices that can block with wax from oil breakdown, moisture that&#8217;s frozen into ice crystals, or metallic debris from compressor wear circulating through the system.</p>



<p>A partially blocked TXV starves the evaporator — the case cools, but not enough to maintain safe temperatures under load. A fully blocked TXV means zero cooling. Wax blockages typically indicate degraded compressor oil in an aging system. Moisture blockages point to a failed or saturated filter drier on the liquid line. The TXV itself can be replaced, but the contamination source needs addressing — otherwise the replacement valve will block in the same way.</p>



<h2 class="wp-block-heading">Evaporator Fan Failure</h2>



<p>The evaporator fans serve two critical functions: they circulate cold air through the case to keep product at temperature, and they maintain the air curtain across the front of the case that prevents warm store air from entering. If a fan motor fails, airflow drops. Cold air pools at the bottom of the case, warm air infiltrates from the top, and the temperature sensor — usually positioned in the return air path — reads high.</p>



<p>Listen to the case. If it&#8217;s quieter than the identical cases either side of it, check the fans. Most display cases have multiple small fan motors, and losing one might not be immediately obvious visually. But the temperature impact is measurable within hours. Fan motors on display cases are a standard replacement item and can usually be swapped without recovering refrigerant.</p>



<h2 class="wp-block-heading">Product Loaded Past the Air Curtain Line</h2>



<p>Every open-front refrigerated display case has a load line — a marked position or shelf height that represents the maximum product level. Products stacked above this line physically break through the air curtain. Warm store air flows directly into the case, the evaporator can&#8217;t cope with the extra heat load, and the temperature climbs. The refrigeration system is working perfectly — the case is just being asked to do more than it was designed for.</p>



<p>This is an operational problem, not a mechanical one. Staff stacking shelves need to understand that overfilling a case above the load line doesn&#8217;t increase sales — it warms the product and creates a food safety risk. Check the load line before calling an engineer. It might save you a call-out charge.</p>



<h2 class="wp-block-heading">Night Blinds Not Being Deployed</h2>



<p>Open display cases are engineered to operate with night blinds — covers pulled down or across the case front when the store is closed. These blinds reduce the refrigeration load dramatically by eliminating warm air infiltration when product visibility is unnecessary. If closing staff aren&#8217;t deploying night blinds, the cases work substantially harder overnight. Compressors run longer, energy consumption spikes, and the entire system operates under stress it was never designed for.</p>

<p>Businesses running <a href="https://adk.co.uk/bitzer-compressor-service-london/">Bitzer</a> equipment can call our dedicated team for same-day diagnosis. We have also written a detailed guide on <a href="https://adk.co.uk/cold-room-evaporator-icing-up/">cold room evaporator icing up</a> which covers a closely related failure mode worth checking.</p>



<p>The cumulative effect of not using night blinds accelerates compressor wear, increases the risk of mechanical failure, and inflates energy bills. Making night blind deployment part of the closing checklist is a management discipline issue with direct mechanical and financial consequences.</p>



<h2 class="wp-block-heading">Compressor Failure on the Rack System</h2>



<p>If multiple cases are running warm simultaneously, the problem is almost certainly upstream at the compressor rack rather than in any individual case. A failed compressor reduces the rack&#8217;s total cooling capacity. The remaining compressors might handle the load during quiet periods, but during peak trading hours — with heavy customer traffic, frequent case door openings, and high ambient temperatures in the store — they can&#8217;t keep up. Suction pressure rises, evaporator temperatures climb, and case temperatures follow.</p>



<p>Check the compressor rack. Are all compressors running? Is one tripped on overload or locked out with an error? Rack compressor failures need urgent attention because they affect multiple cases across multiple product categories simultaneously. One failed compressor can put thousands of pounds worth of chilled stock at risk.</p>



<h2 class="wp-block-heading">Food Safety Compliance</h2>



<p>UK food safety regulations require continuous temperature monitoring of chilled display equipment and documented corrective actions when temperatures breach safe limits. If your chilled case is above 8°C, you should already be following your HACCP procedures: recording the breach, pulling affected product, documenting what corrective action was taken, and retaining records for inspection. Environmental health officers check these records, and gaps in your temperature logs raise immediate red flags.</p>



<p>ADK provides emergency refrigeration repair for supermarkets and food retail across London. We understand the urgency — a warm display case isn&#8217;t just a repair ticket, it&#8217;s a food safety incident with compliance implications. Call us on 0207 801 0808 and we&#8217;ll get an engineer to you fast.</p><p>The post <a href="https://adk.co.uk/supermarket-refrigeration-case-running-warm/">Supermarket Refrigeration Case Running Warm — What to Check</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cold Room Evaporator Icing Up Badly — What&#8217;s Going Wrong</title>
		<link>https://adk.co.uk/cold-room-evaporator-icing-up/</link>
		
		<dc:creator><![CDATA[Omar]]></dc:creator>
		<pubDate>Fri, 13 Mar 2026 11:17:31 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11497</guid>

					<description><![CDATA[<p>The chef opens the cold room first thing in the morning and the evaporator coil is a solid block of ice. Airflow is blocked. The room temperature has climbed overnight — the probe says 8°C and climbing. Product is at risk. This is a refrigeration emergency, and it&#8217;s one of the most common cold room...</p>
<p>The post <a href="https://adk.co.uk/cold-room-evaporator-icing-up/">Cold Room Evaporator Icing Up Badly — What’s Going Wrong</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>The chef opens the cold room first thing in the morning and the evaporator coil is a solid block of ice. Airflow is blocked. The room temperature has climbed overnight — the probe says 8°C and climbing. Product is at risk. This is a refrigeration emergency, and it&#8217;s one of the most common cold room faults we deal with in London restaurants, hotels, and food businesses.</p>



<p>Every cold room evaporator accumulates frost during normal operation. That&#8217;s physics — warm, moist air meets a sub-zero coil and moisture freezes on the surface. But a properly functioning system has a defrost cycle that melts this frost periodically, keeping the coil clear. When that defrost cycle fails, ice builds up fast and the consequences cascade quickly.</p>

<p>Faults like this are common across commercial sites in <a href="https://adk.co.uk/air-conditioning-refrigeration-east-london/">East London</a>. Enrolling in a <a href="https://adk.co.uk/emergency-breakdown-service/">emergency breakdown service</a> schedule helps catch the warning signs early, reducing the chance you will ever need an <a href="https://adk.co.uk/planned-preventative-maintenance/">PPM</a>.</p>



<h2 class="wp-block-heading">How the Defrost Cycle Works</h2>



<p>Before we get into fault causes, it&#8217;s worth understanding how defrost works. Most commercial cold room evaporators use electric defrost heaters — resistive elements embedded in or strapped to the coil. A timer or controller initiates defrost at set intervals (typically two to four times per day), the compressor stops, and the heaters switch on to melt accumulated frost. The meltwater drains into a tray and out through a heated drain line to a collection point outside the cold room.</p>



<p>A defrost termination thermostat monitors the coil temperature. Once the coil reaches a set point — usually around 10°C to 15°C — the thermostat signals that defrost is complete, the heaters switch off, and the compressor restarts. The whole cycle takes 15 to 30 minutes. When any part of this sequence fails, ice accumulates with every operating cycle.</p>



<h2 class="wp-block-heading">Failed Defrost Timer or Controller</h2>



<p>This is the most common cause of evaporator icing. The defrost timer — whether a mechanical clock timer or an electronic controller — is responsible for initiating the defrost cycle. If it fails, defrost never starts. Frost builds from the first hour of operation and gets worse by the day.</p>



<p>Mechanical timers are notorious for sticking. The motor that drives the timer cam can fail, or the contacts can burn and weld shut in the wrong position. Electronic controllers can lose their programming after a power cut, or the controller itself can fail. Either way, no initiation signal means no defrost and a steadily growing block of ice on the coil.</p>



<h2 class="wp-block-heading">Defrost Heater Element Burned Out</h2>



<p>Even if the timer initiates defrost perfectly, the heaters have to actually work. Electric defrost heaters operate in a harsh environment — cycling between sub-zero temperatures and high heat, surrounded by moisture. Over time, the elements corrode and burn out. If one or more heater elements have failed, the defrost cycle runs but doesn&#8217;t generate enough heat to melt the frost completely.</p>



<p>You&#8217;ll often see a pattern: the part of the coil closest to a working heater is clear, while the rest is iced. A resistance check on each heater element quickly identifies which ones have failed. Replacement heaters are specific to the evaporator model but are generally a straightforward swap.</p>



<h2 class="wp-block-heading">Defrost Termination Thermostat Failed</h2>



<p>The termination thermostat tells the system when defrost is complete. If it fails closed (always satisfied), the defrost cycle terminates immediately after starting — the controller thinks the coil is already warm when it isn&#8217;t. The heaters run for seconds instead of minutes, nowhere near long enough to clear the frost.</p>



<p>If it fails open (never satisfied), the defrost runs for the maximum time but that&#8217;s less of an icing problem and more of an energy and temperature-control issue. The failed-closed scenario is the one that causes rapid ice build-up. Testing the thermostat with a multimeter at ambient temperature versus coil temperature confirms whether it&#8217;s switching correctly.</p>



<h2 class="wp-block-heading">Low Refrigerant Charge</h2>



<p>A refrigerant leak causes the evaporator to operate at a lower pressure and temperature than designed. The coil surface drops well below zero — potentially to -25°C or colder — which means frost forms faster and denser than the defrost cycle can cope with. Even a fully functional defrost system can&#8217;t keep up if the coil is running 10 degrees below its design temperature.</p>



<p>Signs of low refrigerant alongside icing include: the compressor running continuously, the cold room struggling to pull down to temperature between defrost cycles, and frost or ice forming unevenly on the coil (concentrated at the inlet). A pressure check confirms the charge level, and the leak needs to be found and repaired before recharging.</p>



<h2 class="wp-block-heading">Damaged Door Gasket</h2>



<p>A torn, compressed, or missing door gasket allows warm, moisture-laden air from the kitchen to constantly infiltrate the cold room. That moisture has to go somewhere — and it ends up as frost on the coldest surface in the room, which is the evaporator coil. The defrost system may be working correctly but simply cannot keep up with the volume of moisture entering through the bad seal.</p>

<p>This problem often goes hand in hand with <a href="https://adk.co.uk/cold-room-compressor-running-constantly/">a cold room compressor running constantly</a>. If you are noticing both symptoms, it is worth getting an engineer out before the system fails completely. We have also covered <a href="https://adk.co.uk/walk-in-freezer-not-holding-temperature/">walk-in freezers not holding temperature</a> in a separate guide.</p>



<p>Close the cold room door and look for daylight around the edges. Feel for cold air escaping. If the gasket is damaged, replacing it is cheap and quick — and it solves the moisture problem at source rather than trying to defrost it away after the fact.</p>



<h2 class="wp-block-heading">Evaporator Fan Not Running</h2>



<p>The evaporator fan circulates cold air around the room and across the coil. If the fan motor fails, air stagnates around the coil surface. Without airflow, moisture in the immediate vicinity of the coil freezes and stays frozen. Ice builds from the coil outward in a dense, solid mass rather than the light frost you&#8217;d normally see.</p>



<p>A failed evaporator fan also means the room warms unevenly — the area near the coil may stay cold while the far end climbs in temperature. Listen for the fan when the compressor is running. If the cold room is quiet, the fan has likely failed and needs replacing.</p>



<h2 class="wp-block-heading">Emergency Response</h2>



<p>A fully iced evaporator is an emergency for any food business. Product temperatures climbing above safe limits means potential stock losses and food safety risk. Step one is to move critical stock to another cold storage if available. Step two is to call an engineer.</p>



<p>ADK provides emergency cold room repair across London. We carry defrost timers, heater elements, termination thermostats, fan motors, and refrigerant for the most common cold room systems. We diagnose the root cause — not just defrost the ice and leave — because if the underlying fault isn&#8217;t fixed, the ice will be back within 24 hours. Call us day or night.</p><p>The post <a href="https://adk.co.uk/cold-room-evaporator-icing-up/">Cold Room Evaporator Icing Up Badly — What’s Going Wrong</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Glycol Chiller Not Cooling Enough — Causes and Solutions</title>
		<link>https://adk.co.uk/glycol-chiller-not-cooling-enough/</link>
		
		<dc:creator><![CDATA[Omar]]></dc:creator>
		<pubDate>Fri, 13 Mar 2026 11:17:29 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11496</guid>

					<description><![CDATA[<p>The beer&#8217;s pouring warm. The glycol chiller is running but the temperature on the tank or at the font keeps climbing. In a brewery, the fermenter won&#8217;t hold temperature. In a process cooling application, the production line is out of spec. The chiller sounds like it&#8217;s working — compressor running, pump on — but the...</p>
<p>The post <a href="https://adk.co.uk/glycol-chiller-not-cooling-enough/">Glycol Chiller Not Cooling Enough — Causes and Solutions</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>The beer&#8217;s pouring warm. The glycol chiller is running but the temperature on the tank or at the font keeps climbing. In a brewery, the fermenter won&#8217;t hold temperature. In a process cooling application, the production line is out of spec. The chiller sounds like it&#8217;s working — compressor running, pump on — but the glycol just isn&#8217;t cold enough. Here&#8217;s what&#8217;s going on.</p>



<p>Glycol cooling systems are straightforward in principle: a chiller cools a glycol-water mix, a pump circulates it through the load, and it comes back warm to be cooled again. When the system can&#8217;t maintain temperature, the fault is either in the chiller, the circulation, or the glycol itself.</p>

<p>We handle this type of problem frequently for businesses in <a href="https://adk.co.uk/air-conditioning-refrigeration-brixton-clapham/">Brixton</a> and the surrounding area. If your system is showing these symptoms, our <a href="https://adk.co.uk/planned-preventative-maintenance/">PPM</a> team can usually diagnose the root cause on the first visit.</p>



<h2 class="wp-block-heading">Low Glycol Level</h2>



<p>The first thing to check and the most common cause. Glycol systems lose fluid over time — from small leaks at fittings, pump seals, or hose connections, and occasionally from evaporation in open or poorly sealed reservoir tanks. When the level drops too low, the pump starts drawing air, circulation becomes erratic, and cooling capacity falls off a cliff.</p>



<p>Check the reservoir tank. If the glycol level is below the minimum mark — or below the pump inlet — top it up with the correct glycol-water mix. Don&#8217;t just add water. Diluting the glycol concentration changes the freeze point and thermal properties of the entire system. And if the level dropped quickly, find the leak before topping up — otherwise you&#8217;ll be doing this again next week.</p>



<h2 class="wp-block-heading">Incorrect Glycol Concentration</h2>



<p>Glycol concentration matters more than most people realise. Too little glycol in the mix and the fluid can freeze inside the chiller&#8217;s evaporator when the system pulls down to low temperatures. Too much glycol and the thermal capacity drops — the fluid can&#8217;t absorb and carry heat as efficiently, which means the system struggles to cool the load even though the chiller is working hard.</p>



<p>For most beer and beverage applications, propylene glycol concentration should be between 30% and 40% by volume, giving a freeze point well below the operating temperature while maintaining good heat transfer. A refractometer check takes two minutes and tells you exactly where the concentration sits. This should be checked annually at minimum.</p>



<h2 class="wp-block-heading">Failed Circulation Pump</h2>



<p>The chiller can be making ice-cold glycol, but if the circulation pump has failed or is running at reduced capacity, that cold glycol never reaches the load. A pump impeller can wear, a motor winding can partially fail (pump runs but slowly), or the pump can seize entirely.</p>



<p>Check the pump — is it running? Is it vibrating normally? Feel the glycol lines either side of the pump. The supply line should be noticeably colder than the return. If both lines are the same temperature, the glycol isn&#8217;t flowing properly. A pump swap is a routine repair that gets the system back online quickly.</p>



<h2 class="wp-block-heading">Dirty Condenser Coil</h2>



<p>The chiller rejects its heat through a condenser coil — either air-cooled or water-cooled. An air-cooled condenser that&#8217;s clogged with dust, fluff, or debris can&#8217;t reject heat efficiently. The compressor runs hotter, head pressure climbs, and cooling capacity drops. In severe cases, the high-pressure safety switch trips and the compressor shuts down altogether.</p>



<p>Look at the condenser coil. If you can&#8217;t see through it, it needs cleaning. In a cellar environment with dust and cardboard fibres in the air, condensers can block up surprisingly fast. A thorough clean with a coil brush and compressed air — working from the clean side out — will often restore full cooling capacity immediately.</p>



<h2 class="wp-block-heading">Compressor Weak or Failed</h2>



<p>If the condenser is clean, the glycol level and concentration are correct, and the pump is circulating, the compressor itself might be the problem. Compressors lose efficiency as they age — valves wear, seals degrade, and the unit can no longer compress refrigerant to the pressures needed for proper heat exchange.</p>



<p>A suction and discharge pressure test will show immediately whether the compressor is pulling its weight. Low discharge pressure and high suction pressure together indicate a weak compressor. At that point, it&#8217;s a compressor replacement or a new chiller unit depending on the age and value of the equipment.</p>

<p>If you are also experiencing <a href="https://adk.co.uk/beer-cellar-cooling-problems/">beer cellar cooling problems</a>, the two faults may share a common cause. Our engineers frequently find that addressing one resolves the other. You might also want to read our guide on <a href="https://adk.co.uk/cellar-cooler-freezing-up/">cellar coolers freezing up</a> for additional troubleshooting steps.</p>



<h2 class="wp-block-heading">Glycol Lines Not Insulated</h2>



<p>Glycol circulates at temperatures well below the ambient air in a cellar or plant room. If the glycol pipework isn&#8217;t insulated — or the insulation has deteriorated — the fluid picks up heat from the surrounding air on its way to the load. On a long pipe run, the heat gain can be significant enough to raise the delivered glycol temperature above what the load requires.</p>



<p>Check the insulation on all glycol lines, particularly in warmer areas like above ceilings, through risers, or past hot water pipes. Any bare copper or steel pipework carrying cold glycol is a heat gain problem and a condensation risk. Proper closed-cell insulation solves both issues.</p>



<h2 class="wp-block-heading">Blocked Strainer in the Glycol Circuit</h2>



<p>Most glycol circuits have a strainer or filter to catch debris. Over time, these block with sediment, pipe scale, or degraded glycol residue — especially in older systems. A blocked strainer restricts flow just like a failed pump would, and the symptoms are identical: the chiller cools the glycol in the tank but it doesn&#8217;t reach the load effectively.</p>



<p>Check and clean the strainer. On systems that haven&#8217;t been maintained, the strainer can be almost completely blocked. While it&#8217;s out, inspect the condition of the glycol itself — if it&#8217;s dark brown or smells off, the glycol has degraded and the entire system needs flushing and refilling.</p>



<h2 class="wp-block-heading">Call ADK</h2>



<p>Glycol chiller systems serve breweries, pubs, wine cellars, bakeries, and industrial process cooling across London. When they underperform, the consequences are immediate — warm beer, failed batches, out-of-spec production. ADK engineers diagnose and repair glycol chiller systems on site, from pump replacements and condenser cleans to full compressor swaps and glycol system recommissions. Call us and we&#8217;ll get your temperatures back where they should be.</p><p>The post <a href="https://adk.co.uk/glycol-chiller-not-cooling-enough/">Glycol Chiller Not Cooling Enough — Causes and Solutions</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Walk-In Freezer Not Holding Temperature — What to Check</title>
		<link>https://adk.co.uk/walk-in-freezer-not-holding-temperature/</link>
		
		<dc:creator><![CDATA[Omar]]></dc:creator>
		<pubDate>Fri, 13 Mar 2026 11:17:23 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11506</guid>

					<description><![CDATA[<p>A catering manager at a hotel in Kensington checked the walk-in freezer at 6am and found it sitting at -10°C. It should have been at -18°C. The HACCP temperature logger had been alarming since 2am but the overnight duty manager had silenced the alert thinking it was a glitch. Four hours of rising temperature with...</p>
<p>The post <a href="https://adk.co.uk/walk-in-freezer-not-holding-temperature/">Walk-In Freezer Not Holding Temperature — What to Check</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>A catering manager at a hotel in Kensington checked the walk-in freezer at 6am and found it sitting at -10°C. It should have been at -18°C. The HACCP temperature logger had been alarming since 2am but the overnight duty manager had silenced the alert thinking it was a glitch. Four hours of rising temperature with £12,000 of frozen seafood, meat, and pastry stock inside. By the time we arrived, the surface temperature of products near the door was already at -8°C and climbing.</p>



<p>A walk-in freezer that can&#8217;t hold -18°C is a ticking clock. Every degree above target accelerates quality loss and eventually creates a food safety problem. The legal requirement under UK food safety regulations is that frozen food must be stored at -18°C or below. Anything above -12°C and you&#8217;re in territory where an EHO would take a very dim view.</p>

<p>We handle this type of problem frequently for businesses in <a href="https://adk.co.uk/air-conditioning-refrigeration-central-london/">Central London</a> and the surrounding area. If your system is showing these symptoms, our <a href="https://adk.co.uk/emergency-breakdown-service/">emergency breakdown service</a> team can usually diagnose the root cause on the first visit.</p>



<p>Here&#8217;s what causes freezers to lose temperature — and what you can do about it.</p>



<h2 class="wp-block-heading">Damaged Door Seals and Strip Curtains</h2>



<p>The door is the weakest point in any walk-in freezer&#8217;s insulation envelope. The primary seal — a heated magnetic gasket around the door frame — prevents warm air ingress and stops ice forming on the frame. Behind the door, most walk-in freezers also have PVC strip curtains that act as a secondary barrier when the door is open during loading.</p>



<p>When the door gasket wears, tears, or loses its magnetic grip, warm moist air enters constantly. You&#8217;ll see the signs: ice buildup around the door frame, frost on the floor near the threshold, and the compressor running longer and harder than normal. Damaged or missing strip curtains make every door opening a major thermal event — warm air floods in and it takes the system minutes to recover.</p>



<p>Replacing door gaskets and strip curtains is one of the most cost-effective freezer repairs. The energy savings alone often pay for the parts within weeks.</p>



<h2 class="wp-block-heading">Defrost Heater Failure and Ice Buildup</h2>



<p>Walk-in freezer evaporators accumulate ice during normal operation — it&#8217;s unavoidable when you&#8217;re cooling air below zero. The defrost system — typically electric heaters embedded in the evaporator coil — activates several times a day to melt this ice and keep the coil clear. The meltwater drains away through a heated drain line.</p>



<p>When a defrost heater element fails, ice builds up on the affected section of the evaporator. Over days, this ice spreads until it encases the entire coil. Airflow through the evaporator drops to almost nothing. The freezer temperature creeps up even though the compressor is running flat out — because the ice is insulating the coil from the air it&#8217;s supposed to be cooling.</p>



<p>If the drain line heater fails, meltwater refreezes in the drain and eventually blocks it. The next defrost cycle produces water with nowhere to go — it pools under the evaporator and freezes into a solid mass on the floor of the freezer. We&#8217;ve chipped out ice blocks the size of a suitcase from neglected drain lines.</p>



<h2 class="wp-block-heading">Dirty Condenser</h2>



<p>The condenser — either remote on the roof or integral to the refrigeration pack — rejects the heat extracted from the freezer. A dirty condenser can&#8217;t reject heat efficiently. Discharge pressure rises, the compressor works harder, energy consumption spikes, and the system gradually loses its ability to pull down to -18°C.</p>



<p>On rooftop condensers, the usual culprits are urban grime, pollen, pigeon feathers, and nesting material. On condensers in plant rooms, poor ventilation compounds the problem. Condenser cleaning is the single most important item on any freezer maintenance schedule.</p>



<h2 class="wp-block-heading">Low Refrigerant From a Leak</h2>



<p>Refrigerant charge should remain constant for the life of the system. If it&#8217;s dropping, there&#8217;s a leak. Low charge reduces the evaporator&#8217;s cooling capacity — the compressor runs longer but can&#8217;t pull the temperature down. In a freezer application, even a 10-15% charge loss can mean the difference between holding -18°C and struggling at -12°C.</p>



<p>Under F-Gas regulations, leaks must be found and repaired before recharging. Simply topping up a leaking system is illegal and pointless — the refrigerant escapes again and you&#8217;re back where you started. We locate leaks using electronic detectors and nitrogen pressure testing, repair the joint or component, vacuum the system, and recharge to the correct weight.</p>



<h2 class="wp-block-heading">Compressor Weakness</h2>



<p>Compressors wear over time. Valve plates erode, piston rings lose their seal, and the compressor&#8217;s pumping efficiency drops. A worn compressor might hold -14°C on a mild day but can&#8217;t pull down to -18°C when ambient temperatures rise or after a defrost cycle. Measuring suction and discharge pressures against the manufacturer&#8217;s expected values tells us whether the compressor is delivering its rated capacity or whether it&#8217;s tired.</p>

<p>This problem often goes hand in hand with <a href="https://adk.co.uk/cold-room-evaporator-icing-up/">cold room evaporator icing up</a>. If you are noticing both symptoms, it is worth getting an engineer out before the system fails completely. We have also covered <a href="https://adk.co.uk/commercial-freezer-loud-noise/">commercial freezer noise problems</a> in a separate guide.</p>



<h2 class="wp-block-heading">Too-Frequent Door Openings</h2>



<p>During a busy service, kitchen staff may open the walk-in freezer door dozens of times in an hour. Every opening lets in a slug of warm, humid air. The system has to cool that air back down and deal with the moisture, which adds to the ice load on the evaporator. If the freezer is borderline — ageing equipment, partially blocked condenser, slightly low on gas — heavy door traffic during peak service can push it over the edge.</p>



<p>Practical solutions: batch your trips to the freezer, keep the door open for the shortest time possible, make sure strip curtains are intact and hanging correctly, and consider a fast-action door if the traffic volume justifies it.</p>



<h2 class="wp-block-heading">Failed Evaporator Fan</h2>



<p>Evaporator fans circulate cold air around the freezer. When one fails, temperature distribution becomes uneven — the area near the coil stays cold while remote corners warm up. The average temperature rises and the temperature logger may alarm even though the coil is still producing cold air. In multi-fan evaporators, losing one fan may not cause an immediate alarm but will gradually degrade performance.</p>



<h2 class="wp-block-heading">HACCP and Temperature Logging</h2>



<p>Under HACCP requirements, freezer temperatures must be monitored and logged. If your system uses an automated logger with alarms, make sure the alarm thresholds are set correctly and that alerts actually reach someone who will act on them. The Kensington hotel we mentioned at the start had the right equipment — they just didn&#8217;t have the right process for responding to overnight alarms.</p>



<h2 class="wp-block-heading">Freezer Not Holding Temperature? Call ADK</h2>



<p>A freezer fault is an emergency. Stock value at risk, compliance at risk, and the clock is ticking. We respond to walk-in freezer breakdowns across London 24/7 with F-Gas certified engineers who carry common parts on every van. Call <strong>020 3974 1419</strong> — we&#8217;ll get your freezer back to -18°C.</p><p>The post <a href="https://adk.co.uk/walk-in-freezer-not-holding-temperature/">Walk-In Freezer Not Holding Temperature — What to Check</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Display Fridge Misting Up Inside — Causes and Fixes</title>
		<link>https://adk.co.uk/display-fridge-misting-up-inside/</link>
		
		<dc:creator><![CDATA[Omar]]></dc:creator>
		<pubDate>Fri, 13 Mar 2026 11:17:20 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11503</guid>

					<description><![CDATA[<p>A deli owner in Islington sent us a photo of his serve-over display counter. The glass was completely misted up from the inside — customers couldn&#8217;t see a thing. He&#8217;d been wiping it down every twenty minutes during the lunch rush, but the condensation came back within five. His staff were opening the sliding doors...</p>
<p>The post <a href="https://adk.co.uk/display-fridge-misting-up-inside/">Display Fridge Misting Up Inside — Causes and Fixes</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>A deli owner in Islington sent us a photo of his serve-over display counter. The glass was completely misted up from the inside — customers couldn&#8217;t see a thing. He&#8217;d been wiping it down every twenty minutes during the lunch rush, but the condensation came back within five. His staff were opening the sliding doors to wipe, which made the problem worse. Sandwiches and salads sitting behind fogged glass don&#8217;t sell. He reckoned he was losing 30% of his lunchtime impulse purchases.</p>



<p>Display fridges exist to display product. When the glass mists up, the fridge fails at its primary job. The food is still cold, but nobody&#8217;s buying what they can&#8217;t see. Here&#8217;s what causes it and how to fix it.</p>

<p>We see this issue regularly in <a href="https://adk.co.uk/air-conditioning-refrigeration-shoreditch/">Shoreditch</a>. A proactive <a href="https://adk.co.uk/planned-preventative-maintenance/">PPM</a> agreement is the best way to prevent this fault from recurring, and it means faster response times if you do need an <a href="https://adk.co.uk/commercial-refrigeration-installation/">refrigeration installation</a>.</p>



<h2 class="wp-block-heading">Worn or Damaged Door Gaskets — The Most Common Cause</h2>



<p>The rubber gaskets around the doors of a display fridge create an airtight seal that keeps warm, humid shop air out of the cold cabinet. When gaskets crack, lose their magnetic grip, tear, or deform from years of use, warm air leaks in continuously. That warm air carries moisture. When the moisture hits the cold glass, it condenses. Misting.</p>



<p>Run your hand slowly around the perimeter of a closed door. If you can feel cold air escaping at any point, the gasket has failed at that section. On multi-door display units, it&#8217;s often the most-used door — the one staff open hundreds of times a day for restocking — that goes first.</p>



<p>Gasket replacement is straightforward and relatively inexpensive. We carry common profiles for the major manufacturers. It&#8217;s one of the highest-value repairs in commercial refrigeration — a new gasket improves display visibility, reduces energy consumption, and extends the life of the compressor by reducing its workload.</p>



<h2 class="wp-block-heading">Failed Anti-Sweat Heaters</h2>



<p>Most glass-door display fridges have low-wattage heaters embedded in the glass panels or the door frames. These anti-sweat heaters keep the glass surface just warm enough to prevent condensation forming on the outside. On some units, heated glass also prevents internal misting by maintaining a slight temperature differential across the pane.</p>



<p>When these heaters fail, the glass temperature drops to match the cabinet interior, and any humidity in the surrounding air condenses on it. The failure can be partial — one door mists while the others stay clear — or total if the heater circuit has tripped or the controller has failed.</p>



<p>Diagnosing a failed anti-sweat heater requires checking the heater resistance and the controller output. On some units, the heaters run continuously; on energy-efficient models, they&#8217;re controlled by a humidity sensor and only activate when condensation risk is high.</p>



<h2 class="wp-block-heading">Overloading and Blocked Airflow</h2>



<p>Display fridges rely on a carefully designed airflow pattern to maintain even temperatures and keep moisture under control. In upright glass-door units, cold air flows from vents at the top or back, circulates across the shelves, and returns to the evaporator at the bottom. Overfilling the shelves or pushing products right up against the back wall and air vents disrupts this airflow.</p>



<p>When circulation stalls, cold spots form near the evaporator while warmer pockets develop near the glass. The temperature differential between the glass surface and the air behind it creates condensation. The solution is disciplined stock loading — follow the load line markers inside the cabinet. They&#8217;re there for a reason.</p>



<h2 class="wp-block-heading">High Ambient Humidity</h2>



<p>Some environments are just harder for display fridges. A shop next to an open kitchen, a deli with a constantly boiling bain-marie, a convenience store in a basement with poor ventilation — all generate high ambient humidity that overwhelms the cabinet&#8217;s ability to manage condensation.</p>



<p>If the gaskets are fine and the anti-sweat heaters are working but you&#8217;re still getting misting, the environment is the problem. Solutions include improving shop ventilation, reducing humidity sources, or upgrading to cabinets with more aggressive anti-condensation systems.</p>



<h2 class="wp-block-heading">Evaporator Fan Failure</h2>



<p>The evaporator fans inside the cabinet circulate cold air and maintain the air curtain effect on open-front displays. When a fan fails, the air curtain collapses and warm shop air floods into the cabinet. On closed-door units, a dead fan creates uneven temperatures and stagnant pockets of moist air that condense on the coldest surfaces — usually the glass.</p>

<p>This problem often goes hand in hand with <a href="https://adk.co.uk/commercial-fridge-not-cooling/">commercial fridge not cooling</a>. If you are noticing both symptoms, it is worth getting an engineer out before the system fails completely. We have also covered <a href="https://adk.co.uk/walk-in-fridge-temperature-too-high/">walk-in fridge temperatures running too high</a> in a separate guide.</p>



<p>Listen for the fans when the cabinet is running. If it&#8217;s quieter than usual or you can see that one of the fan blades isn&#8217;t spinning, that&#8217;s your culprit. Fan motors on display cabinets are small, inexpensive, and quick to replace.</p>



<h2 class="wp-block-heading">Incorrect Temperature Setting</h2>



<p>A cabinet set colder than it needs to be creates a bigger temperature gap between the glass and the surrounding air, increasing condensation risk. If the cabinet is set to 0°C but the products only need 5°C, you&#8217;re creating unnecessary condensation and wasting energy. Set the temperature to the warmest safe point for your product — typically 2–5°C for most chilled display applications.</p>



<h2 class="wp-block-heading">Night Blinds on Open-Front Displays</h2>



<p>Open-front display cabinets — the multideck units common in convenience stores and supermarkets — rely on an air curtain to separate cold cabinet air from warm shop air. During trading hours, this works reasonably well. Overnight, without the air curtain fans running at full speed, these cabinets are vulnerable to humidity ingress.</p>



<p>Night blinds are pull-down covers that seal the open front of the cabinet outside trading hours. Using them consistently reduces overnight energy consumption by up to 30% and dramatically cuts condensation problems the next morning. If your open-front displays are misting up at the start of each day, check whether night blinds are fitted and whether staff are actually using them.</p>



<h2 class="wp-block-heading">Display Fridge Misting Up? Call ADK</h2>



<p>Misted-up display cabinets cost you sales every hour they&#8217;re fogged. We diagnose and fix the root cause — gaskets, heaters, fans, airflow, controls — across all major display fridge brands. Call <strong>020 3974 1419</strong> for a fast response across London.</p><p>The post <a href="https://adk.co.uk/display-fridge-misting-up-inside/">Display Fridge Misting Up Inside — Causes and Fixes</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cellar Cooler Freezing Up — Why Your Beer Cellar Is Too Cold</title>
		<link>https://adk.co.uk/cellar-cooler-freezing-up/</link>
		
		<dc:creator><![CDATA[Omar]]></dc:creator>
		<pubDate>Fri, 13 Mar 2026 11:17:19 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11501</guid>

					<description><![CDATA[<p>A pub landlord in Bermondsey came down to the cellar on a Monday morning and found the beer lines frozen solid. The cellar thermometer read -2°C. Two casks of real ale had been ruined — frozen, expanded, and pushed the shives out. The keg lager was borderline. He&#8217;d lost a weekend&#8217;s worth of cask stock...</p>
<p>The post <a href="https://adk.co.uk/cellar-cooler-freezing-up/">Cellar Cooler Freezing Up — Why Your Beer Cellar Is Too Cold</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>A pub landlord in Bermondsey came down to the cellar on a Monday morning and found the beer lines frozen solid. The cellar thermometer read -2°C. Two casks of real ale had been ruined — frozen, expanded, and pushed the shives out. The keg lager was borderline. He&#8217;d lost a weekend&#8217;s worth of cask stock because the cellar cooler had run all night without switching off.</p>



<p>A beer cellar should sit between 11–13°C for cask ales and around 3–5°C for keg products if you&#8217;re running a remote python system. When the cooler overshoots and the cellar drops below freezing, you&#8217;ve got a fault that needs fixing before it destroys more stock.</p>

<p>We handle this type of problem frequently for businesses in <a href="https://adk.co.uk/air-conditioning-refrigeration-south-london/">South London</a> and the surrounding area. If your system is showing these symptoms, our <a href="https://adk.co.uk/planned-preventative-maintenance/">PPM</a> team can usually diagnose the root cause on the first visit.</p>



<p>Here&#8217;s what actually causes a cellar cooler to freeze up — and what to do about it.</p>



<h2 class="wp-block-heading">Failed or Miscalibrated Thermostat — The Most Common Cause</h2>



<p>The cellar thermostat tells the cooler when to run and when to stop. It&#8217;s a simple concept: cellar gets too warm, cooler kicks in; cellar reaches target temperature, cooler switches off. When the thermostat fails, it either sticks in the &#8220;on&#8221; position — calling for cooling permanently — or drifts out of calibration so it&#8217;s reading the wrong temperature.</p>



<p>Mechanical thermostats with a capillary sensor are common on older cellar coolers. The capillary tube is filled with a gas that expands and contracts with temperature, operating a switch. If the tube gets kinked, the bulb corrodes, or the switch mechanism wears out, the thermostat can stick closed. The cooler runs without stopping until the cellar hits sub-zero temperatures.</p>



<p>Digital controllers are more reliable but not immune. A failed sensor gives the controller a false reading, and it responds accordingly. We&#8217;ve seen controllers reading 18°C when the cellar was actually at 4°C — the system was cooling aggressively against a phantom heat load that didn&#8217;t exist.</p>



<h2 class="wp-block-heading">Stuck-Open Solenoid Valve</h2>



<p>On cellar cooling systems with a remote condensing unit, a solenoid valve in the refrigerant line opens when the thermostat calls for cooling and closes when it&#8217;s satisfied. If the solenoid valve sticks open — usually from a burnt coil or debris on the valve seat — refrigerant flows continuously regardless of what the thermostat says.</p>



<p>The giveaway is that the thermostat clicks off (you can hear it) but the evaporator keeps running cold. The compressor eventually cycles on its own controls, but the damage is done — the cellar overcools between thermostat signal and compressor shutdown. Solenoid valve replacement is a standard repair and usually resolves the issue immediately.</p>



<h2 class="wp-block-heading">Iced-Up Evaporator Coil</h2>



<p>The evaporator coil inside the cellar is where the actual cooling happens. Under normal operation, it runs cold but shouldn&#8217;t ice up. When ice forms on the coil, it insulates the surface and blocks airflow — the system cools less effectively, so it runs longer, which creates more ice. It&#8217;s a downward spiral.</p>



<p>Ice on the evaporator points to one of several problems: low refrigerant charge from a leak (the coil runs colder than design temperature), a failed defrost cycle (if the system has one), a faulty evaporator fan that&#8217;s not moving enough air across the coil, or an ambient cellar temperature that&#8217;s already too cold for the system&#8217;s design parameters.</p>



<p>A cellar cooler with a block of ice on the evaporator needs a controlled defrost — turn it off, let the ice melt completely, then investigate the root cause before restarting. Chipping ice off the coil damages the fins and can puncture the tubing.</p>



<h2 class="wp-block-heading">Poor Cellar Insulation or Ventilation</h2>



<p>Some cellars are naturally cold — underground, stone walls, no heating. In winter, the cellar might sit at 8–10°C without any mechanical cooling. A cooler sized for summer loads will short-cycle or overshoot badly in these conditions because the heat load has dropped to almost nothing.</p>

<p>We have written a separate guide on <a href="https://adk.co.uk/beer-cellar-cooling-problems/">beer cellar cooling problems</a> which covers a related failure mode worth checking. Similarly, our article on <a href="https://adk.co.uk/glycol-chiller-not-cooling-enough/">glycol chillers not cooling enough</a> explains another common cause of the same underlying issue.</p>



<p>Conversely, a poorly ventilated cellar where the condenser is also located in the cellar space creates a heat loop — the condenser dumps heat into the cellar, the cooler removes it, the condenser dumps more. The system works harder than it should, and temperature control becomes erratic.</p>



<p>The condenser needs adequate ventilation to outside air. If it&#8217;s in the cellar, the cellar needs proper airflow to dissipate the rejected heat. Without this, the system fights itself.</p>



<h2 class="wp-block-heading">Getting the Temperature Right</h2>



<p>Target cellar temperatures vary depending on what you&#8217;re storing and serving:</p>



<ul class="wp-block-list">
<li><strong>Cask ale:</strong> 11–13°C — too cold kills the flavour and condition; too warm and it goes off fast</li>
<li><strong>Keg beer and lager:</strong> ideally the cellar sits at 11–13°C with a python cooling system chilling the beer to 3–5°C at the point of dispense</li>
<li><strong>Wine storage:</strong> 10–14°C depending on type</li>
</ul>



<p>A cellar at -2°C is as damaging as one at 20°C. Frozen cask ale is ruined. Frozen keg lines burst fittings. Even bottled stock can crack if the cellar drops far enough below zero.</p>



<h2 class="wp-block-heading">What to Do Right Now</h2>



<ol class="wp-block-list">
<li>Turn the cellar cooler off at the isolator — stop the overcooling immediately</li>
<li>Check the thermostat setting — it should be set between 11–13°C for a standard beer cellar</li>
<li>Look at the evaporator coil — if it&#8217;s a block of ice, leave the cooler off until it&#8217;s fully defrosted</li>
<li>Check if the evaporator fan is running when the cooler is on</li>
<li>Call an engineer to diagnose the root cause before restarting</li>
</ol>



<h2 class="wp-block-heading">Cellar Cooling Problems? Call ADK</h2>



<p>We maintain and repair cellar cooling systems across London&#8217;s pubs, bars, and restaurants. Thermostat replacement, solenoid valves, evaporator defrosts, full system health checks — we carry the parts and know the systems. Call <strong>020 3974 1419</strong> for same-day cellar cooling repairs.</p><p>The post <a href="https://adk.co.uk/cellar-cooler-freezing-up/">Cellar Cooler Freezing Up — Why Your Beer Cellar Is Too Cold</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Refrigerant Leak Signs in Commercial Systems — What to Look For</title>
		<link>https://adk.co.uk/refrigerant-leak-signs-commercial-systems/</link>
		
		<dc:creator><![CDATA[Omar]]></dc:creator>
		<pubDate>Fri, 13 Mar 2026 11:17:03 +0000</pubDate>
				<category><![CDATA[Commercial Refrigeration]]></category>
		<guid isPermaLink="false">https://adk.co.uk/?p=11493</guid>

					<description><![CDATA[<p>A restaurant chain asked us to investigate why their energy bills had increased by 25% across three London sites. No obvious faults — all the systems were running, all the temperatures were roughly where they should be. But &#8220;roughly&#8221; was the key word. Every system across the three sites was running 1-2°C warmer than set...</p>
<p>The post <a href="https://adk.co.uk/refrigerant-leak-signs-commercial-systems/">Refrigerant Leak Signs in Commercial Systems — What to Look For</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>A restaurant chain asked us to investigate why their energy bills had increased by 25% across three London sites. No obvious faults — all the systems were running, all the temperatures were roughly where they should be. But &#8220;roughly&#8221; was the key word. Every system across the three sites was running 1-2°C warmer than set point, and the compressors were running 30% longer than normal. The cause was the same on all three: slow refrigerant leaks that had been losing charge for months. Nobody noticed because the systems still worked — they just worked badly, and the electricity meter noticed even if the staff didn&#8217;t.</p>



<p>Refrigerant leaks are the silent drain on commercial HVAC and refrigeration systems. A system can lose 20-30% of its charge before it actually stops cooling, and in that window it&#8217;s consuming significantly more energy, running the compressor harder, and heading toward a failure that&#8217;ll cost far more to fix than the leak itself.</p>

<p>We see this issue regularly in <a href="https://adk.co.uk/air-conditioning-refrigeration-north-london/">North London</a>. A proactive <a href="https://adk.co.uk/emergency-breakdown-service/">emergency breakdown service</a> agreement is the best way to prevent this fault from recurring, and it means faster response times if you do need an <a href="https://adk.co.uk/planned-preventative-maintenance/">PPM</a>.</p>



<h2 class="wp-block-heading">Visual Signs of a Refrigerant Leak</h2>



<ul class="wp-block-list">
<li><strong>Oil stains around pipework joints</strong> — refrigerant carries compressor oil through the system. Where refrigerant leaks out, oil leaks out too. Look for dark oily residue on pipe connections, flare joints, and valve stems</li>
<li><strong>Ice formation on pipework</strong> — a leak at a specific point can cause localised icing as the refrigerant expands through the leak point. A frost line on a pipe where there shouldn&#8217;t be one is a strong indicator</li>
<li><strong>Bubbles in the sight glass</strong> — if the system has a liquid line sight glass (common on commercial refrigeration), persistent bubbles indicate low charge</li>
<li><strong>Oil on the floor beneath the outdoor unit</strong> — often the first visible sign of a significant leak from the compressor area</li>
</ul>



<h2 class="wp-block-heading">Performance Signs</h2>



<ul class="wp-block-list">
<li><strong>Reduced cooling capacity</strong> — the system runs but doesn&#8217;t cool as well as it used to. Rooms take longer to reach temperature, or never quite get there</li>
<li><strong>Compressor running longer</strong> — longer run times to achieve the same result</li>
<li><strong>Higher energy consumption</strong> — the electricity bill tells the truth even when the thermometer lies</li>
<li><strong>Ice on the evaporator coil</strong> — low refrigerant charge causes the evaporator temperature to drop below freezing, and moisture in the air freezes on the coil</li>
<li><strong>Short cycling</strong> — if the charge drops far enough, the low-pressure switch starts tripping</li>
</ul>



<h2 class="wp-block-heading">F-Gas Regulations and Leak Checks</h2>



<p>Under UK F-Gas regulations, commercial systems above certain charge thresholds must have mandatory leak checks at specified intervals. The purpose is both environmental (fluorinated refrigerants are potent greenhouse gases) and practical (a leaking system is a system heading for failure). Simply topping up a leaking system without finding and repairing the leak is illegal under F-Gas regulations — and it&#8217;s a waste of money because the new refrigerant will leak out the same way.</p>

<p>If you are also experiencing <a href="https://adk.co.uk/condensing-unit-tripping-high-pressure/">condensing units tripping on high pressure</a>, the two faults may share a common cause. Our engineers frequently find that addressing one resolves the other. You might also want to read our guide on <a href="https://adk.co.uk/cold-room-compressor-running-constantly/">a cold room compressor running constantly</a> for additional troubleshooting steps.</p>



<p>If you suspect a leak, call <strong>020 3974 1419</strong>. We&#8217;ll pressure test the system, locate the leak, repair it, and recharge to the correct specification. All F-Gas documentation included.</p><p>The post <a href="https://adk.co.uk/refrigerant-leak-signs-commercial-systems/">Refrigerant Leak Signs in Commercial Systems — What to Look For</a> first appeared on <a href="https://adk.co.uk">ADK Kooling</a>.</p>]]></content:encoded>
					
		
		